Alarm Oam Error-Frame-Seconds-Summary Enable - 3Com S7906E Command Reference Manual

6300 series
Hide thumbs Also See for S7906E:
Table of Contents

Advertisement

The system generates an error frame seconds summary alarm when the number of error frame
seconds (in an error frame second, at least one error frame occurs) in a specific time period (for
example, 1 minute) exceeds the corresponding predefined threshold.
Related commands: alarm oam error-frame-seconds-summary enable.
The commands here take effect only for OAM 2.0 and above.
Examples
# Set the window size and alarm threshold for error frame seconds summary to 800 and 2 on ONU
1/0/1:1.
<Sysname> system-view
[Sysname] interface onu 1/0/1:1
[Sysname-Onu1/0/1:1] alarm oam error-frame-seconds-summary window 800 threshold 2

alarm oam error-frame-seconds-summary enable

Syntax
alarm oam error-frame-seconds-summary enable
undo alarm oam error-frame-seconds-summary enable
View
OLT port view, ONU port view, FTTH view
Default Level
2: System level
Parameters
None
Description
Use the alarm oam error-frame-seconds-summary enable command to enable the error frame
seconds summary alarm.
Use the undo alarm oam error-frame-seconds-summary enable command to disable the error
frame seconds summary alarm.
By default, the error frame seconds summary alarm is enabled.