Connecting The Cable And The Wall Sockets To The Internal S Port (Internal S Bus) - Auerswald COMpact 3000 analog Operating Manual

Table of Contents

Advertisement

Connecting the Cable and the Wall Sockets to the Internal S
Bus)
Warning: Power surges, which can occur during electrical storms, can
cause life-threatening electric shocks or damage/destroy the PBX.
• Lay all the cables inside the building.
• Do not use the S
Requirements:
– Cover panel is removed
– Internal S
port (only provided at the optionally available COMpact S
0
ISDN module)
– Terminators enabled or disabled at the internal S
– Compliance with the maximum distance/line length between the devices, depending on the
bus variant
– 4-core installation cable (e. g. J-Y(St)Y 2x2x0,6), preferably star quad stranding
– Under unfavorable conditions, for example, near a strong transmitter or an electrical power
line: screened cable
– ISDN wall sockets (e. g. IAE or UAE8)
Note: If possible, only use wall sockets of one type.
– Two terminators (100 Ohm; load capacity min. 0.25 W) for any wall socket at the end position
1. Lay the lines according to the selected bus variant.
2. Attach the wires to the four terminal clamps at the internal S
Note: When assigning the individual wires, orient yourself with the identifiers
subsequently listed or refer to VDE 0815 when identifiers deviate.
Physical circuit/
pair 1
Physical circuit/
pair 2
3. Connect the IAE or UAE8 sockets to the terminal clamps at the internal S
COMpact 3000 analog/ISDN/VoIP - Firmware V4.0 - Operating Manual V06 12/2020
Connecting the Cable and the Wall Sockets to the Internal S
ports for connecting a remote extension.
0
0
Cable with Two
Twin Wires
a1
red
b1
black
a2
white
b2
yellow
Installation and Commissioning
Port (Internal S
0
module or COMpact
0
port, depending on the bus variant
port.
0
Cable with Star Quad
without ring
single rings, 17 mm spacing
double rings, 34 mm spacing
double rings, 17 mm spacing
ISDN End Devices
Port (Internal S
Bus)
0
0
0
port.
0
65