Requirements:
– External S
port (only COMpact 3000 ISDN or COMpact ISDN module available as an option)
0
– Configuration manager, opened with sufficient authorisation
1. Open the page CONFIGURATION > PBX time.
2. Select or clear the Automatic ISDN call check box.
Enables the automatic updating of the PBX time if the time is missing.
Disables the automatic updating of the PBX time if the time is missing. (No
other action is required.)
3. In the entry field, enter the telephone number that the PBX should automatically dial.
The following entries are possible:
Up to 16 digits
Digits
Note:
If no telephone number is entered, the PBX automatically initiates a call using
the MSN/DDI first entered.
When entering a telephone number, it should be a connection on which an
automatic machine can accept a call.
Further steps:
– Save your settings before you leave the page.
COMpact 3000 analog/ISDN/VoIP - Firmware V4.0 - Operating Manual V06 12/2020
Switching Automatic PBX Time Updates via ISDN for Missing Time On/Off