Settings
Analogue Connection

Configuring the Reception Amplification

2. In the list field at the top, select the analogue connection.
A page opens for configuring the analogue connection.
3. Open the page Analogue connection > Expert configuration.
4. In the Impedance list field under General info, select the desired setting.
Further steps:
– Save your settings before you leave the page.
Configuring the Reception Amplification
The reception amplification indicates how many decibels the PBX increases all incoming audio
signals.
This is necessary when local audio signals are perceived as too quiet (e.g., the volume of the
speech that is output to the internal subscribers).
The configuration can be made as follows:
• Via the configuration manager
Requirements:
– External analogue port (only COMpact 3000 analogue)
– Configuration manager, opened with sufficient authorisation
– Expert view (click
– Configured prefixes (country prefix and local area code)
1. Open the page CONFIGURATION > External numbers.
2. In the list field at the top, select the analogue connection.
A page opens for configuring the analogue connection.
3. Open the page Analogue connection > Expert configuration.
4. In the Reception amplification list field under General info, select one of the
following options:
0 dB
to
12 decibels.
376
)
+12
dB: The PBX increases all incoming audio signals by 0 to
COMpact 3000 analog/ISDN/VoIP - Firmware V4.0 - Operating Manual V06 12/2020