Switching Busy Tone Detection (Outgoing) For End Of Call On/Off - Auerswald COMpact 3000 analog Operating Manual

Table of Contents

Advertisement

Settings
Analogue Connection

Switching Busy Tone Detection (Outgoing) for End of Call On/Off

3
to 20: The PBX must detect a busy signal sequence for 3 to 20 seconds to
end the call. The purpose of this is to prevent, for example, speech from being
interpreted as a busy signal.
Further steps:
– Save your settings before you leave the page.
Switching Busy Tone Detection (Outgoing) for End of Call On/Off
If busy tone detection is enabled, one of the busy tones transmitted from the central office is
detected by the PBX.
This is necessary for detecting the end of the call connection and to enable the automatic hang-
up of an ISDN telephone.
Note: Deactivate this setting if interference on the external PBX line is inter-
preted as a busy signal and interrupts calls. In this case, the call needs to be
ended on the PBX; the subscriber can do this by hanging up.
Switching this on/off can be done as follows:
• Via the configuration manager
Requirements:
– External analogue port (only COMpact 3000 analogue)
– Configuration manager, opened with sufficient authorisation
– Expert view (click
– Configured prefixes (country prefix and local area code)
1. Open the page CONFIGURATION > External numbers.
2. In the list field at the top, select the analogue connection.
A page opens for configuring the analogue connection.
3. Open the page Analogue connection > Expert configuration.
4. Select or clear the Busy signal detection (outgoing calls) check box under End of
the call.
388
)
COMpact 3000 analog/ISDN/VoIP - Firmware V4.0 - Operating Manual V06 12/2020

Advertisement

Table of Contents
loading

This manual is also suitable for:

Compact 3000 isdnCompact 3000 voip

Table of Contents