Data Transmission (Except In Block Transfer Mode) - Renesas H8SX/1520 Series Hardware Manual

32-bit cisc microcomputer
Hide thumbs Also See for H8SX/1520 Series:
Table of Contents

Advertisement

Section 12 Serial Communication Interface (SCI)
12.7.6

Data Transmission (Except in Block Transfer Mode)

Data transmission in smart card interface mode (except in block transfer mode) is different from
that in normal serial communication interface mode in that an error signal is sampled and data can
be re-transmitted. Figure 12.26 shows the data re-transfer operation during transmission.
1. If an error signal from the receiving end is sampled after one frame of data has been
transmitted, the ERS bit in SSR is set to 1. Here, an ERI interrupt request is generated if the
RIE bit in SCR is set to 1. Clear the ERS bit to 0 before the next parity bit is sampled.
2. For the frame in which an error signal is received, the TEND bit in SSR is not set to 1. Data is
re-transferred from TDR to TSR allowing automatic data retransmission.
3. If no error signal is returned from the receiving end, the ERS bit in SSR is not set to 1.
4. In this case, one frame of data is determined to have been transmitted including re-transfer, and
the TEND bit in SSR is set to 1. Here, a TXI interrupt request is generated if the TIE bit in
SCR is set to 1. Writing transmit data to TDR starts transmission of the next data.
Figure 12.28 shows a sample flowchart for transmission. All the processing steps are
automatically performed using a TXI interrupt request to activate the DMAC. In transmission, the
TEND and TDRE flags in SSR are simultaneously set to 1, thus generating a TXI interrupt request
if the TIE bit in SCR has been set to 1. This activates the DMAC by a TXI request thus allowing
transfer of transmit data if the TXI interrupt request is specified as a source of DMAC activation
beforehand. The TDRE and TEND flags are automatically cleared to 0 at data transfer by the
DMAC. If an error occurs, the SCI automatically re-transmits the same data. During re-
transmission, TEND remains as 0, thus not activating the DMAC. Therefore, the SCI and DMAC
automatically transmit the specified number of bytes, including re-transmission in the case of error
occurrence. However, the ERS flag is not automatically cleared; the ERS flag must be cleared by
previously setting the RIE bit to 1 to enable an ERI interrupt request to be generated at error
occurrence.
When transmitting/receiving data using the DMAC, be sure to set and enable the DMAC prior to
making SCI settings. For DMAC settings, see section 7, DMA Controller (DMAC).
Rev. 3.00 Mar. 14, 2006 Page 434 of 804
REJ09B0104-0300
Downloaded from
Elcodis.com
electronic components distributor

Advertisement

Table of Contents
loading

Table of Contents