Canon imageRUNNER ADVANCE 6075 Series Service Manual page 764

Table of Contents

Advertisement

E
Detail
Location
Item
Code
Code
E808 -0003
-05
Title
Fixing Power Supply error
Remedy
1. Check the clogging of the Fixing Power Supply Cooling
Fan (FM7).
2. Check the clogging of the Louver on right side of the host
machine (Multi-purpose Tray side).
3. Check the connection of the Fixing Power Supply PCB
(PCB10) Output Connector.
4. Replace the Fixing Power Supply PCB (PCB10).
Description Inlet current is 1A or lower for 1 second or longer although the
maximum voltage is output.
E808 -0004
-05
Title
Fixing Power Supply error
Remedy
Replace the Main Driver PCB (PCB2).
Description Detected OFF with 12V of the Main Driver PCB (PCB2)
output.
E808 -0005
-05
Title
12V OFF detection when relay is turned ON
Remedy
1. Check the conduction of the Fixing Thermal Switch 1/2
(TP1/2).
2. Check the drawer between the Fixing Assembly and the
host machine.
3. Check the connection between the Main Driver PCB (PCB2)
and the Fixing Power Supply PCB (PCB10).
4. Replace the Fixing Power Supply Unit.
5. Replace the Main Driver PCB (PCB2).
Description Detected OFF with 12V of the Fixing Power Supply output
after IH relay is turned ON.
E808 -0006
-05
Title
ASIC error
Remedy
Replace the DC Controller PCB (PCB1).
Description ASIC error.
E808 -0007
-05
Title
Fixing Power Supply error
Remedy
1. Check the connection between the Main Driver PCB (PCB2)
and the Fixing Power Supply PCB (PCB10).
2. Replace the Fixing Power Supply PCB with the one for the
correct location (voltage).
3. Replace the DC Controller PCB (PCB1).
Description The detected power voltage differs from the voltage of the
port in the IH Power Supply.
7
Error Code > Error Code > Error Code Details > E804 to E996
Description
7
Error Code > Error Code > Error Code Details > E804 to E996
E
Detail
Location
Item
Code
Code
E808 -0008
-05
Title
Fixing Power Supply error
Remedy
1. Check the connection between the Main Driver PCB (PCB2)
and the Fixing Power Supply PCB (PCB10).
2. Check the connection between the Fixing Power Supply
PCB (PCB10) and the Heater Unit.
3. Replace the Fixing Roller and Heater Unit.
4. Replace the Fixing Power Supply PCB (PCB10).
5. Replace the Main Driver PCB (PCB2).
Description Current fluctuation error.
E808 -0009
-05
Title
Fixing Power Supply error
Remedy
Replace the DC Controller PCB (PCB1).
Description Unable to clear the error flag at power-on.
E820 -0000
-05
Title
Developer Lower Cooling Fan error
Remedy
1. Check the connection of the Connector.
2. Replace the Developer Lower Cooling Fan (FM30).
Description The Fan stop signal is detected for 5 seconds or longer and
retry is failed 4 times in a row although the Developer Lower
Cooling Fan (FM30) is turned ON.
E820 -0001
-05
Title
Developer Upper Cooling Fan error
Remedy
1. Check the connection of the Connector.
2. Replace the Developer Upper Cooling Fan (FM31).
Description The Fan stop signal is detected for 5 seconds or longer and
retry is failed 4 times in a row although the Developer Upper
Cooling Fan (FM31) is turned ON.
E820 -0002
-05
Title
Duplex Driver Cooling Fan error
Remedy
1. Check the connection of the Connector.
2. Replace the Duplex Driver Cooling Fan (FM41).
Description The Fan stop signal is detected for 5 seconds or longer and
retry is failed 4 times in a row although the Duplex Driver
Cooling Fan (FM41) is turned ON.
E824 -0000
-05
Title
Primary Charging Air Supply Fan error
Remedy
1. Check the connection of the Connector.
2. Replace the Primary Charging Air Supply Fan (FM2).
Description The Fan stop signal is detected for 5 seconds or longer and
retry is failed 4 times in a row although the Primary Charging
Air Supply Fan (FM2) is turned ON.
7-79
Description
7-79

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents