Canon imageRUNNER ADVANCE 6075 Series Service Manual page 1183

Table of Contents

Advertisement

13) Put the Signal Cables and the Power Supply Cables through [A] part.
14) Connect the 4 connectors of the Signal Cables and the Power Supply Cables to the
Mirroring Board or Encryption Board.
CAUTION:
• When connecting the Signal Cables, the side labeled "ch.A" or "ch.B" should be
connected to CH A or CH B on the board.
• When connecting the Power Supply Cables, the cable on the Slot.1 side should be
connected to CH A, and the other cable on the Slot.2 side should be connected to
CH B.
B
C H
A
C H
9
Installation > [TYPE-5] 2 Option HDDs (250GB) + HDD Mirroring Kit or HDD Data Encryption & Mirroring Kit > Installation Procedure > Installing th
Power Supply Cable
Signal Cable
Signal Cable
Power Supply Cable
F-9-398
9
Installation > [TYPE-5] 2 Option HDDs (250GB) + HDD Mirroring Kit or HDD Data Encryption & Mirroring Kit > Installation Procedure > Installing th
[A]
Power Supply Cable (570mm; FK2-7831)
x4
CH B
CH A
Power Supply Cable (570mm; FK2-7831)
9-186
Signal Cable
(550mm; FK2-7827)
Signal Cable
(550mm; FK2-7826)
F-9-399
9-186

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents