Separating The Fixing Upper Unit From The Fixing Lower Unit - Canon imageRUNNER ADVANCE 6075 Series Service Manual

Table of Contents

Advertisement

4
Parts Replacement and Clearning > Fixing > Separating the Fixing Upper Unit from the Fixing Lower Unit
CAUIOTN: Points to Caution at Installation
• Be sure to install the Fixing Cleaning Web in the correct direction.
• When installing the Fixing Cleaning Web, be sure to wind the web around the Web
Take-up Roller until the green line on the web disappears from view.
4
Parts Replacement and Clearning > Fixing > Separating the Fixing Upper Unit from the Fixing Lower Unit
Separating the Fixing Upper Unit from the Fixing Lower
Unit
<Preparation>
1. Pull out the Fixing Feed Unit. (Refer to "Removing the Fixing Assembly")
2. Remove the Fixing Assembly. (Refer to page 4-176)
3. Remove the Fixing Front Cover. (Refer to "Removing the Fixing Cleaning Web")
4. Remove the Fixing Drive Unit 1.
4-1) Remove the Fixing Drive Unit 1.
• Wire Saddle
• Edge Saddle
• Reuse Band
• 3 Connectors
• 3 Screws
F-4-325
x3
F-4-326
4-182
x3
F-4-327
4-182