ADJUST

■ AE
COPIER > ADJUST > AE
AE-TBL
Adj of text density at image density adj
Lv.1 Details
To adjust text density according to the adjusted image density.
As the greater value is set, text gets darker.
Use case
When clearing the RAM data of the Reader Controller PCB
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
When clearing the RAM data of the Reader Controller PCB, enter the
value of service label.
Display/adj/set range
1 to 9
Default value
5
8
Service Mode > COPIER > ADJUST > ADJ-XY
T-8-24
8
Service Mode > COPIER > ADJUST > ADJ-XY
■ ADJ-XY
COPIER > ADJUST > ADJ-XY
ADJ-X
Adj of img pstn in book mode: vert scan
Lv.1 Details
To adjust the image reading start position (image leading edge
position) in vertical scanning direction.
When replacing the Reader Controller PCB/clearing RAM data, enter
the value of service label.
When the non-image width is larger than the standard value, set the
smaller value.
When out of original area is copied, set the larger value.
As the value is incremented by 1, the image position moves to the
trailing edge side by 0.1mm.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
Do not use this at the normal service.
Display/adj/set range
1 to 100
Unit
0.1 mm
Default value
29
ADJ-Y
Adj of img pstn in book mode: horz scan
Lv.1 Details
To adjust the image reading start position in horizontal scanning
direction.
When replacing the Reader Controller PCB/clearing RAM data, enter
the value of service label.
When the non-image width is larger than the standard value, set the
smaller value.
When out of original area is copied, set the larger value.
As the value is incremented by 1, the image position moves to the
rear side by 0.1mm.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting value is changed, write the changed value in the
service label.
Display/adj/set range
36 to 236
Unit
0.1 mm
Default value
116
8-64
8-64