Connection - Canon imageRUNNER ADVANCE 6075 Series Service Manual

Table of Contents

Advertisement

7) The message is shown when the system software is successfully copied. Click "OK" button.
6
Troubleshooting > Version upgrade > Version Upgrade via SST > Connection
F-6-77
6
Troubleshooting > Version upgrade > Version Upgrade via SST > Connection

■ Connection

The following IP address is automatically set for this machine at start-up in Download mode.
• IP address:172.16.1.100
• Subnet mask:255.255.255.0
When the PC with SST installed is connected to this machine, change the PC network
address to the following.
• IP address:172.16.1.160
• Subnet mask:255.255.255.0
• Default gateway: arbitrary
CAUTION:
If the PC has the connection to the network, the settings changed to the above-
mentioned may cause network failures due to redundant IP addresses, etc. Ensure that
the PC is disconnected from the network when you change the PC network settings.
Alternatively use the cross cable to connect the PC to this machine.
Preparation
Requirements
• PC with SST Ver. 4.41 or later installed and the system software for this machine is stored
• Cross cable
10Base-T: Category 3 or 5
100Base-T: Category 5
1000Base-T: Enhanced Category 5 (CAT5e) or later
CAUTION:
Disconnect USB memory storage device storage devices if connected.
Communication to SST is disabled in this machine if any USB memory storage device
storage device is recognized. SST and the USB memory storage device storage device
cannot be used concurrently.
6-44
6-44

Hide quick links:

Advertisement

Table of Contents
loading