Canon imageRUNNER ADVANCE 6075 Series Service Manual page 715

Table of Contents

Advertisement

E
Detail
Location
Item
Code
Code
E591 -8002
-05
Title
Scrap full detection error (External 2 Hole Puncher)
Remedy
1. The Scrap Full Detector PCB is faulty.
2. The Punch Controller PCB is faulty.
3. The Finisher Controller PCB is faulty.
Description The voltage of the light received is 2.0 V or more even when
the light emitting duty of the Scrap Full Detector Sensor has
been decreased to 0%.
E592 -8001
-05
Title
Trailing Edge Sensor error (External 2 Hole Puncher)
Remedy
1. The wiring between the LED PCB/Photosensor PCB and
Punch Controller PCB is faulty.
2. The LED PCB and Photosensor PCB is faulty.
3. The Punch Controller PCB is faulty.
4. The Finisher Controller PCB is faulty.
Description The voltage of the light received is 2.5 V or less even when
the light emitting duty of the Trailing Edge Sensor (LED5,
PTR5) has been increased to 66% or more.
E592 -8002
-05
Title
Trailing Edge Sensor error (External 2 Hole Puncher)
Remedy
1. The LED PCB and Photosensor PCB is faulty.
2. The Punch Controller PCB is faulty.
3. The Finisher Controller PCB is faulty.
Description The voltage of the light received is 2.0 V or more even when
the light emitting duty of the Trailing Edge Sensor has been
decreased to 0%.
E592 -8003
-05
Title
Horizontal Registration Sensor 1 error (External 2 Hole
Puncher)
Remedy
1. The wiring between the LED PCB/Photosensor PCB and
Punch Controller PCB is faulty.
2. The LED PCB and Photosensor PCB is faulty.
3. The Punch Controller PCB is faulty.
4. The Finisher Controller PCB is faulty.
Description The voltage of the light received is 2.5 V or less even when
the light emitting duty of the Horizontal Registration Sensor 1
(LED1, PTR1) has been increased to 66% or more.
E592 -8004
-05
Title
Horizontal Registration Sensor 1 error (External 2 Hole
Puncher)
Remedy
1. The LED PCB and Photosensor PCB is faulty.
2. The Punch Controller PCB is faulty.
3. The Finisher Controller PCB is faulty.
Description The voltage of the light received is 2.0 V or more even when
the light emitting duty of the Horizontal Registration Sensor 1
(LED1, PTR1) has been decreased to 0%.
7
Error Code > Error Code > Error Code Details > E500 to E5F6
Description
7
Error Code > Error Code > Error Code Details > E500 to E5F6
E
Detail
Location
Item
Code
Code
E592 -8005
-05
Title
Horizontal Registration Sensor 2 error (External 2 Hole
Puncher)
Remedy
1. The wiring between the LED PCB/Photosensor PCB and
Punch Controller PCB is faulty.
2. The LED PCB and Photosensor PCB is faulty.
3. The Punch Controller PCB is faulty.
4. The Finisher Controller PCB is faulty.
Description The voltage of the light received is 2.5 V or less even when
the light emitting duty of the Horizontal Registration Sensor 2
(LED2, PTR2) has been increased to 66% or more.
E592 -8006
-05
Title
Horizontal Registration Sensor 2 error (External 2 Hole
Puncher)
Remedy
1. The LED PCB and Photosensor PCB is faulty.
2. The Punch Controller PCB is faulty.
3. The Finisher Controller PCB is faulty.
Description The voltage of the light received is 2.0 V or more even when
the light emitting duty of the Horizontal Registration Sensor 2
(LED2, PTR2) has been decreased to 0%.
E592 -8007
-05
Title
Horizontal Registration Sensor 3 error (External 2 Hole
Puncher)
Remedy
1. The wiring between the LED PCB/Photosensor PCB and
Punch Controller PCB is faulty.
2. The LED PCB and Photosensor PCB is faulty.
3. The Punch Controller PCB is faulty.
4. The Finisher Controller PCB is faulty.
Description The voltage of the light received is 2.5 V or less even when
the light emitting duty of the Horizontal Registration Sensor 3
(LED3, PTR3) has been increased to 66% or more.
E592 -8008
-05
Title
Horizontal Registration Sensor 3 error (External 2 Hole
Puncher)
Remedy
1. The LED PCB and Photosensor PCB is faulty.
2. The Punch Controller PCB is faulty.
3. The Finisher Controller PCB is faulty.
Description The voltage of the light received is 2.0 V or more even when
the light emitting duty of the Horizontal Registration Sensor 3
(LED3, PTR3) has been decreased to 0%.
E592 -8009
-05
Title
Horizontal Registration Sensor 4 error (External 2 Hole
Puncher)
Remedy
1. The wiring between the LED PCB/Photosensor PCB and
Punch Controller PCB is faulty.
2. The LED PCB and Photosensor PCB is faulty.
3. The Punch Controller PCB is faulty.
4. The Finisher Controller PCB is faulty.
Description The voltage of the light received is 2.5 V or less even when
the light emitting duty of the Horizontal Registration Sensor 4
(LED4, PTR4) has been increased to 66% or more.
7-30
Description
7-30