Parts Replacement and Clearning > Fixing > Removing the Fixing Roller, Insulating Bush and Thrust Stopper
<Procedure>
1) Place the Fixing Upper Unit as shown in the figure and remove the Fixing Roller Bearing
Retainer.
2) Remove the Fixing Roller Unit.
4
Parts Replacement and Clearning > Fixing > Removing the Fixing Roller, Insulating Bush and Thrust Stopper
3) Remove the Thrust Stopper from the Fixing Roller Unit to remove the Fixing Roller.
Insulating Bush
Bushing
Spacer
Fixing Roller
Thrust Retainer
CAUTION: Points to Caution at Installation
Be sure to locate the groove of the Fixing Roller Bearing inside the Fixing Upper Unit to
install.
F-4-338
CATION: Points to Caution when Replacing the Fixing Roller
Do not reuse the once removed Thrust Stopper.
If the Thrust Stopper is reused, it may come off during printing.
Bearing
Insulating Bush
Bearing
Fixing Roller
4-187
Fixing Roller
Thrust Retainer
Gear
F-4-339
F-4-340