TEST

■ PG
COPIER > TEST > PG
TYPE
Test print
Lv.1 Details
To execute the test print.
Use case
At trouble analysis
Adj/set/operate method Enter the setting value, and then press Start key.
Test print is executed.
Caution
Be sure to return the value to 0 after the test print output.
Display/adj/set range
0 to 50
0: Normal print
1: Grid
2: 17 gradations Tbic rank 2
3: 17 gradations 600dpi (134-line screen or 141-line screen)
4: Solid white
5: Halftone (density: 80H, Tbic rank 2, without image correction)
6: Halftone (density: 80H, 134-line screen or 141-line screen, without
image correction)
7: Solid black
8: Horizontal line (4 dots, 27 spaces)
9: Horizontal line (6 dots, 50 spaces)
10: Horizontal line (2 dots, 3 spaces)
11: Halftone (density: 60H, Tbic rank 2, without image correction)
12: Halftone (density: 80H, 134-line screen or 141-line screen,
without image correction)
13: Halftone (density: 30H, Tbic rank 2, without image correction)
14: Halftone (density: 30H, 134-line screen or 141-line screen,
without image correction)
15-50: For development
Default value
0
8
Service Mode > COPIER > TEST > PG
8
Service Mode > COPIER > TEST > PG
COPIER > TEST > PG
TXPH
Setting of test print image mode
Lv.1 Details
To set the image mode at the time of test print output.
This mode is enabled for test print only.
Use case
At trouble analysis
Display/adj/set range
0 to 6
0: Error diffusion
1: Low screen ruling (approx. 133 to 190 lines)
2: High screen ruling (approx. 200 to 268 lines)
3: Copy screen (approx. 220 lines)
4: REOS screen (no screen structure)
5: Error diffusion (with trailing edge adjustment)
6: High screen ruling (with trailing edge adjustment)
DENS-K
Adj of Bk color density at test print
Lv.1 Details
To adjust Bk color density when performing test print (TYPE=5).
As the greater value is set, the image gets darker.
Use case
At test print (TYPE=5)
Display/adj/set range
0 to 255
PG-PICK
Setting of test print Pickup Cassette
Lv.1 Details
To set the Pickup Cassette for test print output.
Use case
- At trouble analysis
- At test print output
Adj/set/operate method Select the item, and then press OK key.
Display/adj/set range
1 to 8
1: Cassette 1 (Right Deck), 2: Cassette 2 (Left Deck), 3: Cassette
3 (Option Cassette 2), 4: Cassette 4 (Option Cassette 2), 5: Paper
Deck, 6: Multi-purpose Tray, 7 to 8: Not used
2-SIDE
Setting of PG 2-sided mode
Lv.1 Details
To set 1-sided/2-sided print for PG output.
Use case
At trouble analysis
Adj/set/operate method Select the item, and then press OK key.
Display/adj/set range
0 to 1
0: 1-sided, 1: 2-sided
Default value
0
PG-QTY
Setting of PG output quantity
Lv.1 Details
To set the number of sheets for PG output.
Use case
At trouble analysis
Display/adj/set range
1 to 999
Unit
1 sheet
Default value
1