E804 To E996 - Canon imageRUNNER ADVANCE 6075 Series Service Manual

Table of Contents

Advertisement

E
Detail
Location
Item
Code
Code
E753 -0001
-05
Title
Download Error
Remedy
Check the log to find where the download error has been
occurred.
<FIN_E1> Staple Finisher-E1/Booklet Finisher-E1
<G3CCB> Super G3 FAX Board-AF1/Super G3 2nd Line Fax
Board-AF1/Super G3 3rd/4th Line Fax Board-AE1
<G3CCM> Super G3 FAX Board-AF1/Super G3 2nd Line Fax
Board-AF1/Super G3 3rd/4th Line Fax Board-AE1
When any of the above system software is displayed, check if
the target option has been installed.
When the target option has not been installed:
Turn OFF and then ON the main power supply to restore
(since there is no system software to be updated.).
When the target option has been installed:
Check if the accessory is correctly installed and if the target
system software to be downloaded is for the installed option.
Then download the appropriate system software again.
Description System Software Update Error
Error occurs when updating system software of uninstalled
options
E760 -0001
-00
Title
Main Controller PCB 2 internal error
Remedy
1. Turn OFF and then ON the main power.
2. Remove and then install the DDR2-SDRAM (J11 and J13)
on the Main Controller PCB 2.
3. Replace the DDR2-SDRAM on the Main Controller PCB 2.
4. Replace the Main Controller PCB 2.
NOTE:
If the error occurs periodically or it occurs with specific jobs
although it can be solved by turning OFF and then ON the
power, upgrade the system software to the latest version.
Description Error was detected in the Image Processing Chip on the Main
Controller PCB 2.
7
Error Code > Error Code > Error Code Details > E804 to E996
Description
T-7-12
7
Error Code > Error Code > Error Code Details > E804 to E996

■ E804 to E996

E
Detail
Location
Item
Code
Code
E804 -0000
-05
Title
Power Supply Cooling Fan 1/2 error
Remedy
1. Check the connection of the Connector.
2. Replace the Power Supply Cooling Fan 1 (FM14)/Power
Supply Cooling Fan 2 (FM15).
Description The Fan stop signal is detected for 5 seconds or longer and
retry is failed 4 times in a row although the Power Supply
Cooling Fan 1 (FM14)/Power Supply Cooling Fan 2 (FM15) is
turned ON.
The error detection signal cable is shared with the Fans, and
it is not detected with which Fan the error occurs.
E804 -0001
-05
Title
Fixing Power Supply Cooling Fan error
Remedy
1. Check the connection of the Connector.
2. Replace the Fixing Power Supply Cooling Fan (FM7).
Description The Fan stop signal is detected for 1.5 seconds or longer
and retry is failed 4 times in a row although the Fixing Power
Supply Cooling Fan (FM7) is turned ON.
E806 -0000
-05
Title
Making Image Exhaust Fan error
Remedy
1. Check the connection of the Connector.
2. Replace the Making Image Exhaust Fan (FM3).
Description The Fan stop signal is detected for 5 seconds or longer and
retry is failed 4 times in a row although the Making Image
Exhaust Fan (FM3) is turned ON.
E808 -0001
-05
Title
Fixing Power Supply error
Remedy
1. Check the outlet voltage. -> Connect to the correct outlet.
2. Check the connection between the Main Driver PCB (PCB2)
and the Fixing Power Supply PCB (PCB10).
3. Replace the Fixing Power Supply PCB (PCB10).
4. Replace the Main Driver PCB (PCB2).
Description Detected 145V (100V/120V model)/290V (230V model) or
higher inlet voltage at power-on.
E808 -0002
-05
Title
Fixing Power Supply error
Remedy
1. Check the outlet voltage. -> Connect to the correct outlet.
2. Check the connection between the Main Driver PCB (PCB2)
and the Fixing Power Supply PCB (PCB10).
3. Replace the Fixing Power Supply PCB (PCB10).
4. Replace the Main Driver PCB (PCB2).
Description Detected 75 V (100V/120V model)/150 V (230V model) or
higher inlet voltage at power-on.