COPIER > ADJUST > CCD
MTF2-S7
MTF value 7 setting: vert scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-S8
MTF value 8 setting: vert scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-S9
MTF value 9 setting: vert scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
100DF2GB
Img Sensr GB color displace crrct VL:bck
Lv.1 Details
This service mode can be used for the model with Duplex Color
Image Reader Unit-C1 only.
To correct the color displacement (G and B lines) in vertical scanning
direction due to the Scanner Unit (paper back).
When replacing the Reader Controller PCB/clearing RAM data, enter
the value of service label.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-256 to 256
Unit
0.001 line
Default value
0
8
Service Mode > COPIER > ADJUST > CCD
8
Service Mode > COPIER > ADJUST > CCD
COPIER > ADJUST > CCD
100DF2RG
Img Sensr RG color displace crrct VL:bck
Lv.1 Details
This service mode can be used for the model with Duplex Color
Image Reader Unit-C1 only.
To correct the color displacement (R and G lines) in vertical scanning
direction due to the Scanner Unit (paper back).
When replacing the Reader Controller PCB/clearing RAM data, enter
the value of service label.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-256 to 256
Unit
0.001 line
Default value
0
DFCH2R2
Complex chart No.2 data (R) [Front side]
Lv.1 Details
This service mode can be used for the model with Duplex Color
Image Reader Unit-C1 only.
To derive the front/back side linearity, set the Red data (for paper
front) of No.2 image in DADF complex chart.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
1 to 2550
Default value
2000
DFCH2R10
Complex chart No.10 data(R) [Front side]
Lv.1 Details
This service mode can be used for the model with Duplex Color
Image Reader Unit-C1 only.
To derive the front/back side linearity, set the Red data (for paper
front) of No.10 image in DADF complex chart.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 2550
Default value
0
DFCH2B2
Complex chart No.2 data (B) [Front side]
Lv.1 Details
This service mode can be used for the model with Duplex Color
Image Reader Unit-C1 only.
To derive the front/back side linearity, set the Blue data (for paper
front) of No.2 image in DADF complex chart.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
1 to 2550
Default value
2000