Parts Replacement and Clearning > Image Formation System > Removing the Potential Control PCB Unit

Removing the Potential Control PCB Unit

<Preparation>
1. Remove the Primary Charging Assembly Unit.
2. Remove the Pre-transfer Charging Assembly. (Refer to page 4-108)
3. Remove the Process Unit. (Refer to page 4-114)
4. Remove the Hopper Unit. (Refer to page 4-159)
5. Open the Right Door.
6. Remove the Right Upper Cover.
6-1)
Open the Front Upper Cover.
6-2)
Open the Right Door.
6-3)
Open the Box Cover (Right).
6-4)
Remove the Right Upper Cover.
• 2 Screws
• 1 Boss
• 3 Protrusions
x2
4
Parts Replacement and Clearning > Image Formation System > Removing the Potential Control PCB Unit
<Procedure>
1) Remove the Right Door Link Unit from the pin.
• 1 E-ring
2) Remove the Right Shield Plate.
• 2 Screws
x2
F-4-273