Function - Canon imageRUNNER ADVANCE 6075 Series Service Manual

Table of Contents

Advertisement

FUNCTION

SORTER > FUNCTION
FIN-BK-R
Controller PCB backup data read
Lv.1 Details
To read the backup data from Finisher Controller PCB and save to
the hard disk.
Use case
When replacing the Finisher Controller PCB
Adj/set/operate method Select the item, and then press OK key.
Display/adj/set range
During operation: ACTIVE, At normal termination: OK, At abnormal
termination: NG
Required time
Approx. 5 minutes
Related service mode
SORTER> FUNCTION> FIN-BK-W
FIN-BK-W
Controller PCB backup data write
Lv.1 Details
To write the backup data saved on the hard disk to Finisher
Controller PCB.
Use case
When replacing the Finisher Controller PCB
Adj/set/operate method Select the item, and then press OK key.
Display/adj/set range
During operation: ACTIVE, At normal termination: OK, At abnormal
termination: NG
Required time
Approx. 5 minutes
Related service mode
SORTER> FUNCTION> FIN-BK-R
FIN-CON
Controller PCB RAM clear
Lv.1 Details
To execute the RAM clear of Finisher Controller PCB to delete all the
adjustment contents and counter information.
The item can be also set with DIP switch of the Finisher (with
common setting range and setting value). The latest setting value is
enabled regardless of service mode/DIP switch.
Adj/set/operate method 1) Select the item, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
- Output the service mode setting values by P-PRINT before
execution. After execution, enter necessary setting values.
- The RAM data is cleared after the main power switch is turned
OFF/ON.
Related service mode
COPIER> FUNCTION> MISC-P> P-PRINT
PF-CON
Controller PCB RAM clear: PFU
Lv.1 Details
To execute the RAM clear of Inserter/Folder Controller PCB on
Paper Folding Unit to delete all the adjustment contents and counter
information.
Adj/set/operate method Select the item, and then press OK key.
PF-SENS1
Adj Slowdown Timing Sensor output: PFU
Lv.1 Details
To adjust the output of Slowdown Timing Sensor on Paper Folding
Unit automatically.
Use case
- When replacing the Slowdown Timing Sensor
- When replacing the Controller PCB
Adj/set/operate method Select the item, and then press OK key.
8
Service Mode > SORTER > FUNCTION
8
Service Mode > SORTER > FUNCTION
SORTER > FUNCTION
PF-SENS2
Adj Release Timing Sensor output: PFU
Lv.1 Details
To adjust the output of Release Timing Sensor on Paper Folding Unit
automatically.
Use case
- When replacing the Release Timing Sensor
- When replacing the Controller PCB
Adj/set/operate method Select the item, and then press OK key.
PF-SENS3
Adj Fold Position Sensor output: PFU
Lv.1 Details
To adjust the output of Fold Position Sensor on Paper Folding Unit
automatically.
Use case
- When replacing the Fold Position Sensor
- When replacing the Controller PCB
Adj/set/operate method Select the item, and then press OK key.
PF-SENS4
Adj Upper Stopper Path Sensor output:PFU
Lv.1 Details
To adjust the output of Upper Stopper Path Sensor on Paper Folding
Unit automatically.
Use case
- When replacing the Upper Stopper Path Sensor
- When replacing the Controller PCB
Adj/set/operate method Select the item, and then press OK key.
8-212
T-8-90
8-212

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents