■ ANALOG

COPIER > DISPLAY > ANALOG
TEMP
Display of inside temperature
Lv.1 Details
To display the temperature inside the machine detected by
Environment Sensor.
Use case
When checking the temperature inside the machine
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 60
Unit
Deg C
Appropriate target value 20 to 27
Related service mode
COPIER> DISPLAY> ANALOG> HUM, ABS-HUM, PDK-TEMP
HUM
Display of inside humidity
Lv.1 Details
To display the humidity inside the machine detected by Environment
Sensor.
Use case
When checking the humidity inside the machine
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 100
Unit
%
Appropriate target value 30 to 70
Related service mode
COPIER> DISPLAY> ANALOG> TEMP, ABS-HUM, PDK-HUM
ABS-HUM
Display of inside moisture content
Lv.1 Details
To display the absolute moisture content inside the machine detected
by Environment Sensor.
Use case
When checking the moisture content inside the machine
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 100
Unit
g (g/m3)
Appropriate target value 0 to 22
Related service mode
COPIER> DISPLAY> ANALOG> TEMP, HUM
FIX-U
Dis of Fixing Roller center temperature
Lv.1 Details
To display the center temperature of the Fixing Roller detected by
the Fixing Main Thermistor.
Use case
When checking the temperature at the center of Fixing Roller
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 999
Unit
Deg C
FIX-UE
Dis of Fixing Roller edge temperature
Lv.1 Details
To display the edge temperature of the Fixing Roller detected by the
Fixing Sub Thermistor 1.
Fixing Sub Thermistor 1 is located in the rear nip inlet side of Fixing
Roller.
Use case
When checking the edge temperature of the Fixing Roller
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 999
Unit
Deg C
8
Service Mode > COPIER > DISPLAY > ANALOG
8
Service Mode > COPIER > DISPLAY > ANALOG
COPIER > DISPLAY > ANALOG
FIX-SHTR
Display of Fixing Shutter temperature
Lv.1 Details
To display the temperature of the Fixing Shutter detected by the
Fixing Shutter Thermistor.
Use case
When checking the temperature of Fixing Shutter
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 999
Unit
Deg C
PDK-TEMP
Dis of POD Deck compartment temp
Lv.1 Details
To display the compartment temperature of POD Deck Lite.
It may be out of order if the indicated temperature is greatly different
from the machine right after power-on.
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 60
Unit
Deg C
Related service mode
COPIER> DISPLAY> ANALOG> TEMP, PDK-HUM
PDK-HUM
Dis of POD Deck compartment humidity
Lv.1 Details
To display the compartment humidity of POD Deck Lite.
It may be out of order if the indicated temperature is greatly different
from the machine right after power-on.
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 100
Unit
%
Related service mode
COPIER> DISPLAY> ANALOG> HUM, PDK-TEMP