Backup - Canon imageRUNNER ADVANCE 6075 Series Service Manual

Table of Contents

Advertisement

When the new HDD is mounted, the machine cannot be started in the normal procedure.
Start the machine in Safe mode as Download mode. When gaining connection to SST, the
message is shown to confirm if the new HDD is mounted.
Click "Yes" and the message is shown, confirming whether to format HDD.
Click "Initialize" button to initialize HDD (Format ALL). Follow the steps described in Format
ALL section to download the system software.
6
Troubleshooting > Version upgrade > Version Upgrade via SST > Backup
F-6-102
F-6-103
6
Troubleshooting > Version upgrade > Version Upgrade via SST > Backup

■ Backup

● Overview
At the time of replacing controller PCBs, the backup function enables to save data held in the
PCB to migrate them to the new PCB.
• Backup via SST
Backup data
Backup data RAM
SramImg.bin(to be uploaded / downloaded)
MEAP applications
MeapBack.bin(to be uploaded / downloaded)
For investigation in Dev
Sublog.bin(Downloadable)
Service Print
The text file of the contents which You output to paper with a service
mode(Downloadable).
• Backup RAM holds the data from Backup RAM of the Main Controller PCB 2.
(Before replacing the Main Controller PCBs, DC Controller PCB, be sure to back up
the data because Backup RAM holds the parts durable counter data and service mode
setting data in the Main Controller.)
• MeapBack holds MEAP applications and their data stored in HDD
• Backup via Service mode
Backup data
Backup of Reader
COPIER > FUNCTION > SYSTEM RSRAMBUP (Backup)
Controller PCB
COPIER > FUNCTION > SYSTEM RSRAMRES (Restore)
Backup of DC Controller
COPIER > FUNCTION > SYSTEM DSRAMBUP (Backup)
PCB
COPIER > FUNCTION > SYSTEM DSRAMRES (Restore)
Data is stored in HDD
Downloaded/Uploaded file names
Service mode
6-54