Cleaning The Upper Separation Claw - Canon imageRUNNER ADVANCE 6075 Series Service Manual

Table of Contents

Advertisement

4
Parts Replacement and Clearning > Fixing > Cleaning the Upper Separation Claw

Cleaning the Upper Separation Claw

<Preparation>
1. Pull out the Fixing Feed Unit. (Refer to "Removing the Fixing Assembly")
<Procedure>
1) Hold the Lever of the Feed Unit to open the Feed Unit.
2) Clean the Upper Separation Claw with lint-free paper moistened.
4
Parts Replacement and Clearning > Fixing > Cleaning the Upper Separation Claw
F-4-357
F-4-358
3) Wipe toner off the 4 Inner Delivery Rollers with lint-free paper moistened with alcohol.
4-194
F-4-359
4-194