NOTE:
Before replacing the Reader Controller PCBs, back up the data from Service mode.
The backup data can be restored from Service mode when the PCBs are replaced. This
enables to maintain the setting data including Service mode stored in the old Reader
Controller PCB.
Before replacing the DC controller PCBs, back up the data from Service mode. The
backup data can be restored from Service mode when the PCBs are replaced. This
enables to maintain the setting data including Service mode stored in the old Controller
PCB.
Before replacing the Main Controller PCB 2, upload SramImg.bin. By downloading
SramImg.bin after replacement, the new Main Controller PCB 2 inherits the data
including Service mode stored in the old PCB
6
Troubleshooting > Version upgrade > Version Upgrade via SST > Backup
Troubleshooting > Version upgrade > Version Upgrade via SST > Backup
● Steps to Upload Data
CAUTION:
• When the Canon quality-appointed staff determines the need for an analysis of
debug log by the R&D department, we ask the field to collect log for an investigation
to determine the cause.
• The backup data can be downloaded only on the machine from which the data were
uploaded.
• This machine does not use SramRCON and SramDcon
Service PC
SST
iR ----
Upload/Download
System
MeapBack
/ SramImg.bin
Main controller PCB2
SRAM
Listed below are the sample steps to upload MeapBack.
1) Enter Download mode.
2) Connect the PC to the machine to start SST.
iR ADVNCE xxxx Series
Main controller PCB1
HDD
SramImg.bin
Meapback.bin
Main controller
F-6-104