Canon imageRUNNER ADVANCE 6075 Series Service Manual page 973

Table of Contents

Advertisement

■ PRDC-1
COPIER > COUNTER > PRDC-1
PRM-WIRE
Primary Charging Wire parts counter
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
Supplement/memo
This is commonly used as operator maintenance parts counter.
PRM-GRID
Prmry Charge Ass'y Grid Wire parts cntr
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
PO-WIRE
Pre-transfer Charging Wire parts cntr
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
PRM-CLN
Primary Charge Wire Clean Pad prts cntr
Lv.1 Details
Primary Charging Wire Cleaning Pad 1, 2
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
8
Service Mode > COPIER > COUNTER > PRDC-1
8
Service Mode > COPIER > COUNTER > PRDC-1
COPIER > COUNTER > PRDC-1
PO-CLN
Pre-trn Charge Wire Clean Pad prts cntr
Lv.1 Details
Pre-transfer Charging Wire Cleaning Pad 1, 2
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
PO-WI-U
Pre-transfer Charge Wire Unit prts cntr
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
FIX-TH1
Fixing Main Thermistor parts counter
Lv.1 Details
Handle the Fixing Main Thermistor with the Fixing Shutter Thermistor
as 1 part.
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
FIX-TH2
Fixing Sub Thermistor parts counter
Lv.1 Details
Fixing Sub Thermistor 1, Fixing Shutter Thermistor
Handle the Fixing Shutter Thermistor with the Fixing Main Thermistor
as 1 part.
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
8-191
8-191

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents