4
Parts Replacement and Clearning > Image Formation System > Removing the Cleaner Separation Claw

Cleaning the Drum edges

<Preparation>
1. Open the Inner Cover. (Refer to "Removing the Primary Charging Assembly")
2. Remove the Primary Charging Assembly. (Refer to page 4-97)
3. Remove the Pre-transfer Charging Assembly. (Refer to page 4-108)
4. Remove the Process Unit. (Refer to page 4-114)
5. Put paper on the Photosensitive Drum, so that it is not exposed to direct sunlight.
6. Remove the Drum Cleaning Blade. (Refer to page 4-118)
7. Remove the Drum Retainer Plate.
8. Remove the Drum Unit. (Refer to page 4-121)
<Procedure>
1) Rotate the Drum and dry wipe the soiling on the surface of the Drum edges with lint-free
paper.
4
Parts Replacement and Clearning > Image Formation System > Removing the Cleaner Separation Claw

Removing the Cleaner Separation Claw

<Preparation>
1. Open the Inner Cover. (Refer to "Removing the Primary Charging Assembly")
2. Remove the Primary Charging Assembly. (Refer to page 4-97)
3. Remove the Pre-transfer Charging Assembly. (Refer to page 4-108)
4. Remove the Process Unit. (Refer to page 4-114)
5. Remove the Drum Cleaning Blade. (Refer to page 4-118)
6. Remove the Drum Unit. (Refer to page 4-121)
<Procedure>
1) Put the Process Unit Frame perpendiculararly.
2) Remove the 3 Cleaner Separation Claws.
• 1 Spring each
F-4-162
4-127
Cleaner Separation
Claws
Spring
F-4-163
4-127