Canon imageRUNNER ADVANCE 6075 Series Service Manual page 592

Table of Contents

Advertisement

13) Pull out the Duplex Right Roller and remove the shaft at the rear.
NOTE:
In this procedure, the procedure for removing the Duplex Right Roller is shown in steps
13 and 14. When removing the Duplex Outlet Roller, check the installation position in
step 15 and remove the Duplex Outlet Roller by a similar procedure.
CAUTION: Points to Caution at Work
• Be careful not to damage the surfaces of the Duplex Right Roller and the Duplex
Outlet Roller.
• The bearing at the front and the bushing at the rear of the Duplex Right/Duplex
Outlet Roller are not fixed, so be careful not to drop them.
Bushing
6
Troubleshooting > Image Faults > Image error due to soil attached to the Cleaning Brushes for the Duplex Right Roller and the Duplex Outlet Roller
Bearing
Bushing
6
Troubleshooting > Image Faults > Image error due to soil attached to the Cleaning Brushes for the Duplex Right Roller and the Duplex Outlet Roller
14) Move the Duplex Right Roller toward the rear and remove the shaft from the Fixing Feed
Unit Side Plate. Then, move the Duplex Right Roller in the direction of the arrow and take it
out from the opening on the top of the Fixing Feed Unit.
15) Remove the Duplex Outlet Roller in a similar procedure referring to the procedure for
removing the Duplex Right Roller in steps 13 and 14.
NOTE:
The installation position of the Duplex Outlet Roller is shown in the following figure.
F-6-27
F-6-28
6-16
F-6-29
F-6-30
6-16