Canon imageRUNNER ADVANCE 6075 Series Service Manual page 695

Table of Contents

Advertisement

E
Detail
Location
Item
Code
Code
E061 -0101
-05
Title
Potential control error (VD)
Remedy
1. Check the connection of the Pre-exposure LED (connector
connection, open circuit, the caught cable).
2. If the current value of the Primary Charging Roller (COPIER
> DISPLAY > DPOT > PRIM-C) is 1550 micro A or higher,
execute 2-1 to 3.
2-1. Increase the grid voltage of the Primary Charging
2-2. Execute the potential control (COPIER >
2-3. Turn OFF and then ON the power.
3. Check the installation of the Primary Charging Assembly
(connector connection, open circuit, the caught cable).
4. Check the installation of the Primary Charging High Voltage
PCB (PCB11), and its connection (connector connection,
open circuit, the caught cable).
5. Check the installation of the Drum Motor (M1), and its
connection (connector connection, open circuit, the caught
cable).
6. Replace the parts.
• Primary Charging Assembly
• Primary Charging High Voltage PCB
• Drum Motor (M1)
• Main Driver PCB (PCB2)
• DC Controller PCB (PCB1)
Description Potential in the dark area did not fall within the range (target
value +/-10V) although retry was executed 8 times at VD
potential control.
E064 -00FF
-05
Title
High voltage setting error
Remedy
1. Turn OFF and then ON the main power.
2. Replace the DCON PCB.
Description With the state in which the developing AC is output, 600V or
higher developing DC output was detected.
(Basically, this error is not detected. However, to detect that
the image formation-related backup data is corrupted or to
protect the hardware in case of 600V or higher developing
DC output, this is to be an error.)
7
Error Code > Error Code > Error Code Details > E000 to E069
Description
Assembly by 100V (COPIER > ADJUST > HV-PRI
> PRI-GRID).
FUNCTION > DPC > DPC).
7
Error Code > Error Code > Error Code Details > E000 to E069
E
Detail
Location
Item
Code
Code
E065 -0001
-05
Title
Primary charging/grid high voltage output leak error
Remedy
1. Check the connection between the Main Driver PCB (PCB2)
and the High Voltage Unit.
Main Driver side: J111, High Voltage Unit side: J3097
2. Check the connection between the Relay PCB (PCB5) and
the High Voltage Unit.
Relay side: J519, High Voltage Unit side: J3099
3. Replace the Primary Charging Assembly.
4. Check the connection inside of the High Voltage Unit.
High Voltage Unit Relay (J3097) and Primary Charging
High Voltage PCB (PCB11) (J3501)
High Voltage Unit relay (J3099) and Pre-transfer Charging
PCB (PCB26) (J3545, J3500)
5. Replace the Main Driver PCB (PCB2).
6. Replace the Primary Grid High Voltage Connector (FM4-
1006).
Description The leak detection signal was detected 5 times in a row for
every 20 msec.
7-10
Description
7-10

Hide quick links: