Technology > Embedded RDS > Error code and strings
No. Code
Error strings
Cause
10 8xxx
Server certificate
The server certificate
2029
verify error
verification error occurred.
11
8xxx
Server certificate
• The route certificate
2046
expired
registered with the device
has expired.
• Certificate other than
that initially registered
in the user's operating
environment is being used,
but has not been registered
with the device.
• The device time and date
is outside of the certificated
period.
12 8xxx
Unknown error
Some other kind of
2000
communication error has
occurred.
13 8xxx
SOAP Fault
SOAP communication error
2063
has occurred.
14 8xxx
Server response
Communication with UGW
2004
error (NULL)
has been successful, but
an error of some sort has
prevented UGW from
responding.
When (Null) is displayed
at the end of the message,
this indicates that there has
been an error in the HTTPS
communication method.
15 8xxx
Server
Communication with UGW
2004
response error
has been successful, but
([Hexadecimal])
an error of some sort has
[Error detailed in
prevented UGW from
the UGW]
*1
responding.
16 8xxx
Device internal
An internal error, such as
0101 -
error
memory unavailable, etc.,
0A01
has occurred during a device
internal error phase.
17 8xxx
Server schedule is
During the communication
0201 -
invalid
test, there has been some
0204,
kind of error in the schedule
0206
values passed from UGW.
2
Technology > Embedded RDS > Error code and strings
Remedy
Check that the value of URL of
UGW (RGW-ADR) is https://a01.
ugwdevice.net/ugw/agentif010.
Check that the device time and date
are correctly set.
If the device time and date are
correct, upgrade to the latest system
software.
Try again after a period of time.
If the error persists, check the UGW
status with the UGW administrator.
Check that the value of port number
of UGW (RGW-PORT) is 443.
Try again after a period of time.
If the error persists, check the UGW
status with the UGW administrator.
Try again after a period of time.
Check detailed error code
(hexadecimal) from UGW displayed
after the message.
Turn the device OFF/ ON.
Or replace the device system
software. (Upgrade)
When the error occurs, report the
details to the support section.
And then, after the UGW side has
responded, try the communication
test again.
No. Code
Error strings
Cause
18 8xxx
Server response
Due to network congestion,
2047
time out
etc., the response from UGW
does not come within the
specified time. (HTTPS level
time out)
19 8xxx
Service not found
There is a mistake in the
2048
UGW URL, and UGW cannot
be accessed. (Path is wrong)
20 0xxx
E-RDS switch is set
A communication test has
0003
OFF
been attempted with the
E-RDS switch being OFF.
21 0xxx
Server schedule is
Blank schedule data have
0003
not exist
been received from UGW.
22 8xxx
Network is not
Communication attempted
2003
ready, try later
without confirming network
connection, just after booting
up a device in which the
network preparations are not
ready.
23 8xxx
URL error
The data which is not URL is
2052
inputted into URL field.
24 8xxx
Server address
Server address name
200B
resolution error
resolution has failed.
25 0xxx
Communication test
Communication test has not
0003
is not performed
completed.
26 8xxx
Server specified list
Alert filtering error: The
0221
is too big
number of elements of the
list specified by the server is
over restriction value.
27 8xxx
Server specified list
Alert filtering error: Unjust
0222
is wrong
value is included in the
element of the list specified
by the server.
28 xxxx
SUSPEND:
Internal error occurred at the
xxxx
Initialize Failure!
initiating E-RDS.
29 8300
SRAM version
Improper value is written
0306
unmatch!
in at the head of the Main
Controller PCB 2 SRAM
domain of E-RDS.
30 8300
SRAM AeRDS
Improper value is written
0306
version unmatch!
in at the head of the Main
Controller PCB 2 SRAM
domain of Ae-RDS.
31 8xxx
Device is busy, try
The semaphore consumption
0304
later
error at the time of a
communication test.
2-237
Remedy
If this error occurs when the
communication test is being run or
Service Browser is being set, try
again after a period of time.
Check that the value of URL of
UGW (RGW-ADR) is https://a01.
ugwdevice.net/ugw/agentif010.
Set E-RDS switch (E-RDS) to 1, and
then perform a communication test
(COM-TEST).
Check the device settings status
with the UGW administrator.
Check the network connection, as
per the initial procedures described
in the troubleshooting.
Perform a communication test
(COM-TEST) about 60 seconds
later, after turn on the device.
Check that the value of URL of
UGW (RGW-ADR) is https://a01.
ugwdevice.net/ugw/agentif010.
Check that the value of URL of
UGW (RGW-ADR) is https://a01.
ugwdevice.net/ugw/agentif010.
Perform and complete a
communication test (COM-TEST).
The number of elements of alert
filtering is specified correctly.
The element of alert filtering is
specified with the right value.
Turn the device OFF/ ON.
Turn the device OFF/ ON.
Turn the device OFF/ ON.
Try again a communication test after
a period of time.
2-237