Parts Replacement and Clearning > Image Formation System > Removing the Primary Charging Wire Cleaner, Cleaner Holder (Right/Left)
<Procedure>
CAUTION:
Do not move the Charging Wire Shutter; otherwise, the shutter can be damaged when
installing the Charging Assembly. When the Charging Wire Shutter is moved by chance,
be sure to move the Shutter until it is invisible.
CAUTION:
Do not remove both Shield Plates (Right and Left) of the Primary Charging Assembly at
the same time. Be sure to work on one Shield Plate at a time (otherwise, the Frame of
the Primary Charging Assembly can be deformed).
4
Parts Replacement and Clearning > Image Formation System > Removing the Primary Charging Wire Cleaner, Cleaner Holder (Right/Left)
Charging Wire Shutter
Primary Charging Wire Cleaner
F-4-91
1) Remove the Shield Plate (Right). When removing the Primary Charging Wire Cleaner
Holder (Left), remove the Shield Plate (Left).
• 2 Screws
x2
2) Loosen the screw to move the Primary Charging Assembly Cleaner to the center.
Loosen
4-99
F-4-92
F-4-93
4-99