Table of Contents

Advertisement

■ DPOT

COPIER > DISPLAY > DPOT
DPOT-K
Display of Bk Drum surface potential
Lv.1 Details
To display the current surface potential Vd on the Bk Photosensitive
Drum that is specified as a result of the potential control.
The value after the calculation of potential offset is displayed.
If the offset value is not adjusted, negative value may be detected
during printing.
Use case
When the density failure or foggy image occurs, check whether the
surface potential of the Drum is the factor.
Adj/set/operate method N/A (Display only)
Caution
- To update the display, be sure to move to a different screen, and
then move back to display it again. (The potential at the moment of
showing this screen is displayed.)
- If the value is out of range (-30 to 30), there is a possibility of
Potential Sensor disconnection.
Display/adj/set range
-30 to 600
Unit
V
VL1T
Dis of bright area target potential VL
Lv.1 Details
To display the bright area target potential value.
Adj/set/operate method N/A (Display only)
Unit
V
VL1M
Dis of bright area measured potential VL
Lv.1 Details
To display the bright area measured potential value.
Adj/set/operate method N/A (Display only)
Unit
V
VDT
Dis of dark area target potential VL
Lv.1 Details
To display the dark area target potential value.
Adj/set/operate method N/A (Display only)
Unit
V
VDM
Dis of dark area measured potential VL
Lv.1 Details
To display the dark area measured potential value.
Adj/set/operate method N/A (Display only)
Unit
V
BIAS-C
Dis of dev bias potential control result
Lv.2 Details
To display the developing bias potential control result.
Adj/set/operate method N/A (Display only)
Unit
V
LPOWER-C
Output laser intnsty potntl ctrl result
Lv.2 Details
To display the output laser intensity potential control result.
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 255
8
Service Mode > COPIER > DISPLAY > DPOT
8
Service Mode > COPIER > DISPLAY > DPOT
COPIER > DISPLAY > DPOT
PRIM-C
Dis pry chg current potntl ctrl result
Lv.2 Details
To display the potential control result of primary charging current.
Adj/set/operate method N/A (Display only)
Unit
micro A
Related service mode
COPIER > ADJUST > HV-PRI > PRI-GRID
VLT-L
Bright area target potential VL: thin
Lv.1 Details
To display the bright area target potential VL with thin paper.
Use case
At occurrence of an image density failure
Adj/set/operate method N/A (Display only)
Display/adj/set range
50 to 500
Unit
1 V
VLT-H1
Bright area target potential VL: heavy 1
Lv.1 Details
To display the bright area target potential VL with heavy paper 1.
Use case
At occurrence of an image density failure
Adj/set/operate method N/A (Display only)
Display/adj/set range
50 to 500
Unit
1 V
VLT-H2
Bright area target potential VL: heavy 2
Lv.1 Details
To display the bright area target potential VL with heavy paper 2.
Use case
At occurrence of an image density failure
Adj/set/operate method N/A (Display only)
Display/adj/set range
50 to 500
Unit
1 V
8-38
T-8-9
8-38

Hide quick links: