Canon imageRUNNER ADVANCE 6075 Series Service Manual page 692

Table of Contents

Advertisement

E
Detail
Location
Item
Code
Code
E020 -0003
-05
Title
Error in the Toner Excess Supply Sensor connection detection
Remedy
1. Check the connection of the Toner Excess Supply Sensor
(TS2).
Sensor side: J2038, J3124 (relay), J3090 (relay) PCB side:
J3091(relay), J115 (Main Driver PCB (PCB2))
2. Replace the Toner Excess Supply Sensor (TS2).
3. Replace the Main Driver PCB (PCB2).
4. Replace the DC Controller PCB (PCB1).
Description The connection detection port was OFF at power-on.
E020 -0004
-05
Title
Error in Magnet Roller Clutch connection detection
Remedy
1. Check the connection of the Magnet Roller Clutch (CL5).
Sensor side: J2036, J3124 (relay), J3090 (relay) PCB side:
J3091(relay), J115 (Main Driver PCB (PCB2))
2. Replace the Magnet Roller Clutch (CL5).
3. Replace the Main Driver PCB (PCB2).
4. Replace the DC Controller PCB (PCB1).
Description The connection detection port was OFF at power-on.
E020 -0020
-05
Title
Error in Developing Assembly Toner Sensor Cleaning Scraper
displacement
Remedy
1. Turn OFF the main power.
2. Replace the Developing Assembly.
3. Turn ON the main power.
Description State without toner was detected continuously.
E020 -0021
-05
Title
Error in Developing Assembly Toner Sensor Cleaning Scraper
displacement
Remedy
1. Turn OFF the main power.
2. Replace the Developing Assembly.
3. Turn ON the main power.
Description State with toner was detected continuously.
E023 -0001
-05
Title
Developing Motor error
Remedy
1. Check the connection of the Connector.
Motor side: J2319, Main Driver PCB (PCB2) side: J109
2. Check the voltage of the Developing Motor (M2) J2152.
If voltage is 0V, check the connection of the Relay PCB
J520.
3. Check the load of the Developing Motor (M2).
Manually turn the Developing Motor (M2) located at the
rear of the host machine to check it.
4. Replace the Developing Motor (M2).
5. Replace the Developing Clutch (CL1). (When an error
occurs while the Developing Clutch is ON.)
6. Replace the Main Driver PCB (PCB2).
7. Replace the DC Controller PCB (PCB1).
Description Lock error of the Developing Motor (M2).
7
Error Code > Error Code > Error Code Details > E000 to E069
Description
7
Error Code > Error Code > Error Code Details > E000 to E069
E
Detail
Location
Item
Code
Code
E023 -0002
-05
Title
Error in Magnet Roller Clutch connection detection
Remedy
1. Check the connection of the Magnet Roller Clutch (CL5).
Sensor side: J2006, Main Driver PCB (PCB2) side: J109
2. Replace the Magnet Roller Clutch (CL5).
3. Replace the Main Driver PCB (PCB2).
4. Replace the DC Controller PCB (PCB1).
Description Connection of the Magnet Roller Clutch (CL5) cannot be
detected 5 times with 20 msec time interval.
E025 -0001
-05
Title
Toner Feed Motor error
Remedy
1. Check the connection of the Connector.
Motor side: J2036, Buffer Unit relay: J3124, Front side
relay: J3090, Rear side relay: J3091, Main Driver PCB
(PCB2) side: J115
2. Replace the Toner Feed Motor (M28).
3. Check if toner is clogged inside of the Buffer.
Turn the Drive Shaft of the Motor with your hand to check
it. If the load is too much, inside of the Buffer may be
clogged, so clean inside of it.
4. Replace the Main Driver PCB (PCB2).
5. Replace the DC Controller PCB (PCB1).
Description Overcurrent of the Toner Feed Motor (M28) was detected.
E027 -0001
-05
Title
Toner Supply Motor error
Remedy
1. Check the connection of the Connector.
Motor side: J2037, Front side relay: J3080, Rear side relay:
J3063, Main Driver PCB (PCB2) side: J117
2. Remove the Toner Container, and check if an error occurs.
If an error does not occur, reinstall the Toner Container and
check again. If an error occurs, check the driving area of
connection point of the container.
If an error occurs, go on to 3.
3. Replace the Toner Supply Motor (M10).
4. Replace the Main Driver PCB (PCB2).
5. Replace the DC Controller PCB (PCB1).
Description Lock error of the Toner Supply Motor (M10).
E032 -0001
-00
Title
Failure of NE Controller Counter
Remedy
Disconnection of cable.
Description Detection of open circuit of count pulse signal.
E041 -0001
-05
Title
Right Deck Lifter Motor error
Remedy
1. Check for displacement of the Lifter Wire of the Right Deck.
2. Check for hindrance to smooth movement of the Deck
Base Plate of the Right Deck.
Description Overcurrent of the Right Deck Lifter Motor was detected.
7-7
Description
7-7

Hide quick links:

Advertisement

Table of Contents
loading