Alarm
Title
Code
31-0008
HDD failure prediction
Movement: HDD failure is expected to occur in a short time due
alarm
Cause: Error in the S.M.A.R.T. value of HDD
Measures:
1. Back up the data stored in HDD.
2. Replace the HDD.
3. Restore the data.
S.M.A.R.T. (Self-Monitoring Analysis and Reporting
Technology): Self-diagnosis function built in the HDD. The
occurrence rate of reading error, reading and writing speed, the
total number of Motor start-up and stop times, the total length
of power-on time, etc. are monitored.
32-0002
Potential control (VL
Movement: Not reflecting the result of VL control. To the laser
control) error
Cause: The measured value in the dark area (VL) differs over
+/-10V but less than +/-30V than the target potential at
potential control.
Measures: If there is no influence on image, measures are not
1. Check the installation of the Pre-exposure LED (connector
connection, open circuit, the caught cable).
2. Check the installation of the Primary Charging Assembly
(connector connection, open circuit, the caught cable).
3. Check the fixation state of the Drum and the Drum Shaft
(check if the drum fixation cylinder is properly installed).
4. Check if the Dustproof Glass is soiled. If necessary, clean it.
5. Check the installation of the Laser Scanner Unit (connector
connection, open circuit, the caught cable).
6. Check the installation and connection of the Primary
Charging High Voltage PCB (PCB11) (connector connection,
open circuit, the caught cable).
7. Check the installation of the Potential Sensor (connector
connection, open circuit, the caught cable).
8. Check the installation and connection of the Drum Motor (M1)
(connector connection, open circuit, the caught cable).
9. Replace the parts.
• Primary Charging Assembly
• Laser Scanner Unit
• Potential Sensor
• Primary Charging High Voltage PCB (PCB11)
• Drum Motor (M1)
• Main Driver PCB (PCB2)
• DC Controller PCB (PCB1)
7
Error Code > Alarm Code > List of Alarm Code
A. movement /B. cause /C. measures
to occurrence of physical error in HDD. It does not
occur in the HDD of mirroring configuration.
power determined with VL control, the power with
which the previous potential control was succeeded
(within target potential +/-10V) is applied.
needed. If not, execute the following measures.
7
Error Code > Alarm Code > List of Alarm Code
Alarm
Title
Code
33-0001
Delivery Assembly
Movement: No change.
Decurler Fan alarm
Cause: Connector disconnection of the Paper Cooling Fan
(FM5).
Failure of the Paper Cooling Fan (FM5).
Measures: Check the connector -> Replace the Paper Cooling
33-0002
Feed Fan alarm
Movement: No change.
Cause: Connector disconnection of the Registration Motor/
Duplex Motor Cooling Fan (FM42).
Failure of the Registration Motor/Duplex Motor Cooling
Fan (FM42).
Measures: Check the connector -> Replace the Registration
33-0010
Stream Reading Fan
Movement: Nothing in particular (Fan stops).
alarm
Cause: The Fan rotation signal cannot be detected after 3
seconds have passed since the Scanner Unit Heat
Exhaust Fan (FM1) is turned ON.
Measures: Check the connector connection -> Replace the
33-0013
Power Unit Fan 1
Movement: No change.
alarm
Cause: Connector disconnection of the Feed Driver Cooling
Fan (FM40).
Failure of the Feed Driver Cooling Fan (FM40).
Measures: Check the connector -> Replace the Feed Driver
33-0022
Read Motor Cooling
Movement: Nothing in particular (Fan stops).
Fan alarm
Cause: The Fan rotation signal cannot be detected after 3
seconds have passed since the Motor Driver Cooling
Fan (FM1) or the Read Motor Cooling Fan (FM2) is
turned ON.
Measures: Check the connector connection -> Replace the
33-0023
Scanner Unit (DADF)
Movement: Nothing in particular (Fan stops).
Cooling Fan alarm
Cause: The Fan rotation signal cannot be detected after 3
seconds have passed since the (DADF) Scanner Unit
Cooling Fan (FM3) is turned ON.
Measures: Check the connector connection -> Replace the
33-0025
Scanner Unit (Reader)
Movement: Nothing in particular (Fan stops).
Cooling Fan alarm
Cause: The Fan rotation signal cannot be detected after 3
seconds have passed since the (Reader) Scanner Unit
Cooling Fan (FM2) is turned ON.
Measures: Check the connector connection -> Replace the
A. movement /B. cause /C. measures
Fan (FM5).
Motor/Duplex Motor Cooling Fan (FM42).
Scanner Unit Heat Exhaust Fan (FM1).
Cooling Fan (FM40).
Motor Driver Cooling Fan (FM1) or the Read Motor
Cooling Fan (FM2).
DADF Scanner Unit Cooling Fan (FM3).
(Reader) Scanner Unit Cooling Fan (FM2).