Initializing E-Rds Settings - Canon imageRUNNER ADVANCE 6075 Series Service Manual

Table of Contents

Advertisement

2
Technology > Embedded RDS > E-RDS Setup > Initializing E-RDS settings
3. Reboot the device.
4. Make sure that "1 (: ACTIVE)" is set under [COPIER] > [Display] > [USER] > [BRWS-STS].
5. When the above-shown setting values are enabled, [Service Browser] is displayed in the
Service Mode screen.
2
Technology > Embedded RDS > E-RDS Setup > Initializing E-RDS settings

■ Initializing E-RDS settings

It is possible to return E-RDS Settings to factory-shipments value.
● Initialization procedure
1. Start [Service Mode] at Level 1.
For the procedures, see "Steps to E-RDS settings - step 1.".
2. Select [COPIER] > [Function] > [CLEAR] > [ERDS-DAT] and then touch [OK].
F-2-342
● Setting values and data to be initialized
The following E-RDS settings, internal data, and Alarm filtering information are initialized.
• COPIER > Function > INSTALL > E-RDS
• COPIER > Function > INSTALL > RGW-ADR
• COPIER > Function > INSTALL > RGW-PORT
• COPIER > Function > INSTALL > COM-LOG
CAUTION:
In case of replacing the CA certificate file, even if initialization of E-RDS is executed, the
F-2-343
status is not returned to the factory default.
When installing the certificate file other than the factory default CA certificate file, it is
required to delete the certificate file after E-RDS initialization and install the factory
default CA certificate file.
For detailed procedures, see "Steps to E-RDS settings - step 3.".
2-230
F-2-344
2-230