Cst-Sts; Hv-Sts - Canon imageRUNNER ADVANCE 6075 Series Service Manual

Table of Contents

Advertisement

■ CST-STS

COPIER > DISPLAY > CST-STS
WIDTH-C3
Display of Cassette 3 paper size
Lv.2 Details
To display the paper size of Cassette 3.
Use case
When checking the paper size of Cassette 3
Adj/set/operate method N/A (Display only)
WIDTH-C4
Display of Cassette 4 paper size
Lv.2 Details
To display the paper size of Cassette 4.
Use case
When checking the paper size of Cassette 4
Adj/set/operate method N/A (Display only)
WIDTH-MF
Dis of Multi-purpose Tray ppr width size
Lv.2 Details
To display the paper width size set on the Multi-purpose Tray.
Use case
When checking the paper width side set on the Multi-purpose Tray
Adj/set/operate method N/A (Display only)
Unit
mm
8
Service Mode > COPIER > DISPLAY > HV-STS
T-8-6
8
Service Mode > COPIER > DISPLAY > HV-STS

■ HV-STS

COPIER > DISPLAY > HV-STS
PRIMARY
Display of primary charging current
Lv.1 Details
To display the current that is applied to the Primacy Charging
Assembly at the latest.
The result set in COPIER> ADJUST> HV-PRI> PRIMARY is
reflected.
Use case
When checking ON/OFF of potential control
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1600
Unit
micro A
Related service mode
COPIER> ADJUST> HV-PRI> PRIMARY
PRI-GRID
Dis of Primary Charging Ass'y grid bias
Lv.1 Details
To display the grid bias voltage that is applied to the Primacy
Charging Assembly at the latest.
The result set in COPIER> ADJUST> HV-PRI> PRI-GRID is
reflected.
Use case
When checking ON/OFF of potential control
Adj/set/operate method N/A (Display only)
Display/adj/set range
500 to 900
Unit
1 V
Related service mode
COPIER> ADJUST> HV-PRI> PRI-GRID
PRE-TR
Dis of pre-transfer charge DC current
Lv.1 Details
To display the DC component of current that is applied to the Pre-
transfer Charging Assembly at the latest.
Use case
For checking
Adj/set/operate method N/A (Display only)
Display/adj/set range
-650 to 0
Unit
micro A
TR
Dis of transfer current: Plain, 1st side
Lv.1 Details
To display the current that is applied to plain paper (1st side) in the
Pre-transfer Charging Assembly at the latest.
Use case
For checking
Adj/set/operate method N/A (Display only)
Unit
micro A
BIAS
Dis of developing DC bias setting VL
Lv.1 Details
To display the setting value of developing DC bias.
Use case
For checking
Adj/set/operate method N/A (Display only)
Unit
V
TR-V
Dis of ATVC detection voltage value
Lv.1 Details
To display the ATVC detection voltage value.
Use case
For checking
Adj/set/operate method N/A (Display only)
Unit
V