4
Parts Replacement and Clearning > Pickup/Feed System > Removing the Main Drive Unit
4) Remove the Shield Plate.
• 2 Screws
• 2 Protrusions
x2
5) Remove the Waste Toner Container Shutter Unit.
• 3 Screws
x3
CAUTION:
When removing the Waste Toner Container Shutter Unit, be careful of toner scattering.
4
Parts Replacement and Clearning > Pickup/Feed System > Removing the Main Drive Unit
NOTE:
When installing the Waste Toner Container Shutter Unit, be sure to follow the order as
shown in the figure to tighten screws.
F-4-460
6) Remove the Feed Driver PCB Unit.
• 4 Screws
• 13 Connectors
• 9 Wire Saddles
• 1 Reuse Band
• Harness
F-4-461
x3
x4
x13
4-226
F-4-462
F-4-463
4-226