Img-Dev - Canon imageRUNNER ADVANCE 6075 Series Service Manual

Table of Contents

Advertisement

■ IMG-DEV

COPIER > OPTION > IMG-DEV
TSPLY-SW
[Not used]
Lv.2 Details
-
DV-RT-LG
Set Developing Assembly idle rotn time
Lv.1 Details
To set the duration of idle rotation of the Developing Assembly by
COPIER> FUNCTION> MISC-P> DV-RT.
As the value is incremented by 1, the duration is increased by 1
minute.
+: Increase
-: Decrease
Use case
When an image failure is not alleviated by executing idle rotation
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
If the duration is long, deterioration of developer or toner scattering
might occur.
Display/adj/set range
1 to 20
Unit
1 minute
Default value
5
Related service mode
COPIER> FUNCTION> MISC-P> DV-RT
ADJ-VPPN
Adj developing bias Vpp: Uncoated paper
Lv.1 Details
To adjust Vpp of the developing AC bias for uncoated paper group.
The initial value is 1.5 kV, and as the value is decreased by 1, Vpp is
decreased by 0.1 kV (density and fogging increase).
Increase the value when fogging or bias leak occurs, and decrease
the value when the density is low or white spots occur.
Use case
When fogging, bias leak, low density, or white spots occur
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
-4 to 2
Unit
0.1 kV
Default value
0
Supplement/memo
Uncoated paper group: uncoated paper/recycled paper/textured
paper/label/postcard/cotton
DRM-IDL2
Set first idle rotn time in NN Ev
Lv.1 Details
To set the duration of idle rotation to be performed first time for the
day in an NN (normal temperature/normal humidity) environment.
Use case
When image density for the first time of the day is low
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 20 (0: OFF)
Unit
30 seconds
Default value
1 (15 seconds)
Related service mode
COPIER> OPTION> IMG-DEV> DRM-IDL, DRM-IDL3
8
Service Mode > COPIER > OPTION > IMG-DEV
8
Service Mode > COPIER > OPTION > IMG-DEV
COPIER > OPTION > IMG-DEV
ATM
Set of highland ev voltg reduction mode
Lv.2 Details
To set the highland environment voltage reduction mode in the case
that leak occurs at a high latitude.
When 1 is set, high voltage settings for the Primary Charging
Assembly, Pre-transfer Charging Assembly and developing bias are
decreased so that leak can be prevented.
Use case
When leak occurs at high latitude
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: Normal, 1: Voltage reduction mode
Default value
0
LWDTY-SW
ON/OFF of low duty ejection
Lv.1 Details
To set ON/OFF of low duty ejection control.
When 1 is set, developer is ejected at the time of last rotation/during
a job.
Use case
When density is lowered at the time of continuous output of low duty
image
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Set 1 when using a low duty image frequently.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
Related service mode
COPIER> OPTION> IMG-DEV> LWDTYADJ
LWDTYADJ
Set low duty ejection threshold value
Lv.1 Details
To set offset of image density which becomes the threshold value for
the low duty ejection control.
The threshold value which becomes a reference differs depending
on the environment (temperature and humidity).
When a positive value is entered, the interval of low duty ejection
control becomes shorter. Lowering of image density can be
prevented, but replacement timing of the Waste Toner Container
becomes early due to the increase of toner consumption.
Use case
When density is lowered at the time of continuous output of low duty
image
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
-50 to 50
Unit
0.1%
Default value
0
Related service mode
COPIER> OPTION> IMG-DEV> LWDTY-SW
8-131
8-131