4
Parts Replacement and Clearning > Image Formation System > Removing the Potential Control PCB Unit
3) Remove the Potential Control Tray.
• 3 Screws
• 2 Connectors
• Wire Saddle
x3
x2
4) Remove the Potential Sensor Control PCB.
• 1 Screw
• 4 Claws
• 2 Connectors
x2
x4
4
Parts Replacement and Clearning > Image Formation System > Removing the Potential Control PCB Unit
5) Remove the harness.
• 1 Connector
• Edge Saddle
• Wire Saddle
F-4-276
6) Remove the Potential Sensor.
• 1 Screw
F-4-277
4-167
F-4-278
F-4-279
4-167