Canon imageRUNNER ADVANCE 6075 Series Service Manual page 850

Table of Contents

Advertisement

COPIER > ADJUST > CCD
MTF2-M6
MTF value 6 setting: horz scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-M7
MTF value 7 setting: horz scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-M8
MTF value 8 setting: horz scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-M9
MTF value 9 setting: horz scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-S1
MTF value 1 setting: vert scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
8
Service Mode > COPIER > ADJUST > CCD
8
Service Mode > COPIER > ADJUST > CCD
COPIER > ADJUST > CCD
MTF2-S2
MTF value 2 setting: vert scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-S3
MTF value 3 setting: vert scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-S4
MTF value 4 setting: vert scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-S5
MTF value 5 setting: vert scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-S6
MTF value 6 setting: vert scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
8-68
8-68

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents