Points to Caution at Installation:
Check that the long hole of the Sleeve Bias Plate is fitted with the hole of
the Developing Cylinder Blade. If it is not fitted, rotate the Sleeve Bias Plate
counterclockwise to match the phase.
Be careful not to rotate the Sleeve Bias Plate clockwise since this direction is to be a
reverse direction of the proper Developing Cylinder rotation.
4
Parts Replacement and Clearning > Image Formation System > Removing the Developing Cylinder and the Developing Roller
Points to Caution at Installation:
Find the position in which either scale of Sleeve Bias Plate is most matched with one
of the Developing Cylinder Blade scales.
(If the Developing Cylinder Blade is not marked with scales, put a mark on the
Developing Cylinder Blade at a point that matches one of the scales on the Sleeve
Bias Plate and use the point as a reference point.)
See the Sleeve Bias Plate from the front side, and from the most matched position
(scales), rotate the plate clockwise by 3 scales of the Developing Cylinder Blade.
With the position where the plate was rotated by 3 scales, hold the Sleeve Bias Plate
and secure with the removed screw.
This is a reverse direction of the proper Developing Cylinder rotation, but this would be
no problem in this procedure.
F-4-181
4-134
F-4-182