Chassis Management and Monitoring Commands
temp-threshold
Sets the warning temperature threshold for the switch.
temp-threshold temp
Syntax Definitions
temp
Defaults
parameter
temp
Platforms Supported
OmniSwitch 10K
Usage Guidelines
•
N/A
Examples
-> temp-threshold 45
Release History
Release 7.1.1; command introduced.
Related Commands
show fantray
MIB Objects
chasChassisTable
chasTempThreshold
OmniSwitch CLI Reference Guide
The new temperature threshold value, in Celsius.
default
70
Displays the ambient temperature of the current operating chassis, as well
as current temperature threshold settings.
March 2011
temp-threshold
page 38-15