temp-threshold

Sets the CPU warning temperature threshold for the switch.
temp-threshold temp slot slot-number
Syntax Definitions
temp
slot-number
Defaults
parameter
temp
Platforms Supported
OmniSwitch 6250
Usage Guidelines
Use the
show temperature
Do not use the
show health threshold
Examples
-> temp-threshold 45
-> temp-threshold 55 slot 2
Release History
Release 6.6.1; command was introduced.
Related Commands
show temperature
MIB Objects
chasChassisTable
chasTempThreshold
OmniSwitch 6250 CLI Reference Guide
The new temperature threshold value, in Celsius (0–105; 0–91 on
OS6250-P24).
The chassis slot number for which the CPU warning temperature thresh-
old is set.
default
95
86 (OS6250-P24)
command to display the current value for the temerpature warning threshold.
command as it does not display temperature threshold information.
Displays the current operating chassis ambient temperature, as well as cur-
rent temperature threshold settings.