3Com S7906E Command Reference Manual page 302

6300 series
Hide thumbs Also See for S7906E:
Table of Contents

Advertisement

Level: 1
VLAN: 1
Administrative state: Active
FNG state: FNG_DEFECT_REPORTED
CCM:
Current state: CCI_WAITING
Interval: 1s
SendCCM: 12018
Loopback:
NextSeqNumber: 8877
SendLBR: 0
Linktrace:
NextSeqNumber: 8877
SendLTR: 0
No CCM from some remote MEPs is received.
One or more streams of error CCMs are received. The last-received CCM:
Maintenance domain: mdtest1
Maintenance association: matest1
MEP ID: 5
Sequence Number: 0x34fc
MAC Address: 0000-FC00-6504
Received Time: 2008/05/06 16:33:09
One or more streams of cross-connect CCMs is received. The last-received CCM:
Maintenance domain:mdtest1
Maintenance association:matest1
MEP:6
Sequence Number:0x63A
MAC Address 0000-FC00-6503
Received Time: 2008/05/06 16:33:15
Some other MEPs are transmitting the RDI bit.
Table 1-9 display cfd mep command output description
Field
Interface
Maintenance domain
Maintenance association
Level
VLAN
Direction
Administrative state
CCM send
Direction: Outbound
CCM send: Enable
ReceiveInOrderLBR: 0
ReceiveLTM: 0
Interface that an MD belongs to
MD that a MEP belongs to
MA that a MEP belongs to
Level of the MD
VLAN that the MA belongs to
Direction of the MEPs
State of MEP, either Active or Inactive
Whether the MEP sends CCM
1-17
ReceiveOutOrderLBR: 0
Description