Cfd Enable - 3Com S7906E Command Reference Manual

6300 series
Hide thumbs Also See for S7906E:
Table of Contents

Advertisement

View
System view
Default level
2: System level
Parameters
interval-field-value: Value of the interval field in CCM messages, ranging from 5 to 7.
service-instance instance-id: Specifies the service instance ID, ranging from 1 to 32767.
Description
Use the cfd cc interval command to set the value of the interval field in the CCM messages.
Use the undo cfd cc interval command to restore the value to the default value.
By default, the value of this field is 5 for all CCMs sent.
The relationship between the interval field value in the CCM messages, the time interval to send CCM
messages and the timeout time of the remote MEP is illustrated in
Table 1-1 Relationship of interval field value, time interval for sending CCMs and timeout time of
remote MEP
Interval field value
5
6
7
Related commands: cfd cc enable.
Examples
# Set the value of the interval field in CCMs to 7.
<Sysname> system-view
[Sysname] cfd cc interval 7 service-instance 2

cfd enable

Syntax
cfd enable
undo cfd enable
View
System view
Default level
2: System level
Time interval for CCM
1 second
10 seconds
60 seconds
1-2
Table
1-1.
Timeout time of remote MEP
3.5 seconds
35 seconds
210 seconds