042-310 Main Motor Failure Rap; 042-323 Drum Motor Failure Rap - Xerox workcentre 5335 series Service Manual

Table of Contents

Advertisement

042-310 Main Motor Failure RAP

BSD-ON:
BSD 4.1 - Main Drive Control
The Main Motor is not rotating at the specified speed.
Initial Actions
Power OFF/ON
Reload the Xero/Developer Cartridge
Procedure
Close the LH Cover and the Front Cover.
Execute
Component Control
[042-003 Main Motor ON]. The Main Motor can be heard.
Y
N
Go to
BSD 4.1 - Main Drive Control
P/J408) and the Main Motor (
P205
and P204) for an open or short circuit. If OK replace
the Main Motor
(PL
3.2)
Check the installation of the Main Drive Assembly
Assembly is installed correctly.
Y
N
Install the Main Drive Assembly correctly.
Check the wire between P/J407-9 and P205-8 for an open circuit or a short circuit
Main Drive
Control). The wires are conducting without an open circuit or a short circuit.
Y
N
Repair the open circuit or short circuit.
Manually rotate the Main Motor rotor. It rotates smoothly.
Y
N
Check for foreign substances that are interfering with operation or installation failure.
Foreign substances or installation failure are found.
Y
N
Replace the Main Drive Assembly
Remove the foreign substances that are interfering with operation and correct the installa-
tion failure.
Replace the Main Drive Assembly
(PL
3.1) If the problem persists, replace the MCU PWB
18.2).
Initial Issue
WorkCentre 5335 Family Service Documentation
(PL
8.1) and the Fuser Unit
(PL
7.1).
and the wires between the MCU PWB (
P/J407
(PL 3.1
and
PL
3.2). The
Main
(PL
3.1).
BUS Updated 12/2011

042-323 Drum Motor Failure RAP

BSD-ON:
BSD 9.5 Drum Drive Control
The Main Motor is not rotating at the specified speed.
Initial Actions
Power OFF/ON
Reload the Xero/Developer Cartridge
Procedure
Close the LH Cover and the Front Cover.
Execute
Component Control
Y
N
and
Go to
BSD 9.5 Drum Drive Control
J408) and the Main Motor (
the Drum Motor
(PL
3.2)
Drive
Check the installation of the Main Drive Assembly
Assembly is installed correctly.
Y
N
Install the Main Drive Assembly correctly.
(BSD 4.1 -
Check the wire between P/J407-1 and P/J207-8 for an open circuit or a short circuit
Drum Drive
Control). The wires are conducting without an open circuit or a short circuit.
Y
N
Repair the open circuit or short circuit.
Manually rotate the Drum Motor rotor. It rotates smoothly.
Y
N
Check for foreign substances that are interfering with operation or installation failure.
Foreign substances or installation failure are found.
Y
N
Replace the Main Drive Assembly
Remove the foreign substances that are interfering with operation and correct the installa-
tion failure.
(PL
Replace the Main Drive Assembly
18.2).
07/2011
2-763
(PL
8.1) and the Fuser Unit
[042-001 Drum Motor ON]. The Drum Motor can be heard.
and the wires between the MCU PWB (
P/J202
and P/J207) for an open or short circuit. If OK replace
(PL 3.1
and
PL
3.2). The
(PL
3.1).
(PL
3.1) If the problem persists, replace the MCU PWB
042-310, 042-323
(PL
7.1).
P/J407
and
P/
Main
Drive
(BSD 9.5
(PL
Status Indicator RAPs