Figure 4 Ground Plate Alignment
Repairs & Adjustments
REP 5.7, REP 5.8

REP 5.8 Right Counter Balance

Parts List on
Removal
Left/Right Counter Balance is identified by its spring pressure.
Left Counter Balance: strong spring pressure
Right Counter Balance: weak spring pressure
1.
Switch off the power and disconnect the power cord.
2.
Remove the DADF Rear Cover.
3.
Remove the DADF.
4.
Take note of the graduation of the scale.
5.
Remove the Right Counter Balance.
(1) Remove the self-tapping screws (Large: x3).
(2) Remove the screw (Small: x1) and remove the Ground Wire.
(3) Remove the right Counter Balance.
07/2011
4-20
BUS Updated 12/2011
PL 51.3
CAUTION
(REP
5.4)
(REP
5.1)
(Figure
1)
Figure 1 Graduation Scale Marks