127-337 Job Template HDD Write RAP
There was a file access failure during internal polling or an error occurred when writing to the
HDD Job Template sector.
Initial Actions
Power Off/On
Procedure
•
Ask customer to cancel and rerun the job.
•
Turn the power OFF then ON. If the problem persists, perform the following procedure to
repair it.
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the HDD, ESS, MCU all PWBs connected to them (RAM,
Firmware module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB
(PL
•
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB and RAM
DIMM.)
•
If the problem persists perform
NVM
•
Perform
GP 14
- only the first two parts - make sure to follow sequence and heed cau-
tions
1.
Job Log Clear Mode
2.
HDD Initialize Mode
•
Replace HDD
(PL
35.2)
Initial Issue
WorkCentre 5335 Family Service Documentation
35.2)
Read/Write.
BUS Updated 12/2011
127-342 Job Template Monitor RAP
A system function recall error is detected.
Initial Actions
Power Off/On
Procedure
•
Ask customer to cancel and rerun the job.
•
Turn the power OFF then ON. If the problem persists, perform the following procedure to
repair it.
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the HDD, ESS, MCU all PWBs connected to them (RAM,
Firmware module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB
•
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB and RAM
DIMM.)
07/2011
2-993
(PL
35.2)
Status Indicator RAPs
127-337, 127-342