077-900 Registration Sensor Static Jam RAP
BSD-ON:
BSD 8.5 - Registration
When the power was turned ON, the M/C was stopped (Cycle Down/ Shut Down), or when the
interlocks were closed (all interlocks including options), the Registration Sensor detected
paper.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
•
The Registration Sensor for remaining paper, contamination, Actuator return failure, or
improper installation
•
The Registration Sensor for failure:
Component Control
•
The connection between the Registration Sensor
open circuit, short circuit, and poor contact
Reload the machine software
(GP
16). If no problems are found, replace the MCU PWB
18.2).
Status Indicator RAPs
077-900, 077-901
[077-104]
(PL
15.1)
P/J121
and the MCU PWB
P/J415
for
(PL
07/2011
2-812
BUS Updated 12/2011
077-901 Exit Sensor 1 Static Jam RAP
BSD-ON:
BSD 10.2 - Fusing
When the power was turned ON, the M/C was stopped (Cycle Down/ Shut Down), or when the
interlocks were closed (all interlocks including options), the Fuser Exit Sensor detected paper.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
•
The Fuser Exit Sensor for remaining paper, contamination, Actuator return failure, or
improper installation
•
The Fuser Exit Sensor for failure:
Component Control
Reload the machine software
(GP
16). If no problems are found, replace the MCU PWB
18.2).
[077-101]
(PL
7.1)
Initial Issue
WorkCentre 5335 Family Service Documentation
(PL