116-342 SESAMi Manager Fail RAP

An internal shutdown occurred due to an error in processing SNMP (Simple Network Manage-
ment Protocol).
Initial Actions
Power Off/On
Procedure
Reload Software
(GP
16).
Status Indicator RAPs
116-342, 116-343

116-343 Main PWB IC RAP

An error is detected in the IC in the ESS PWB.
Initial Actions
Power Off/On
Procedure
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
Check the sw version of the controller sw - update if required
Replace RAM DIMM on ESS PWB
Replace ESS PWB
07/2011
2-862
BUS Updated 12/2011
(PL
35.2)
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB)