077-902 Exit Sensor 2 Static Jam RAP
BSD-ON:
BSD 10.3 - Exit Transportation
When the power was turned ON, the M/C was stopped (Cycle Down/ Shut Down), or when the
interlocks were closed (all interlocks including options), the Exit 2 Sensor detected paper.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
•
The Exit 2 Sensor for remaining paper, contamination, Actuator return failure, or improper
installation
•
The Exit 2 Sensor for failure:
Component Control
•
The connection between the Exit 2 Sensor
circuit, short circuit, and poor contact
•
The L/H Upper Cover Assembly for damage or mismatch
Reload the machine software
(GP
16). If no problems are found, replace the MCU PWB
18.2).
Initial Issue
WorkCentre 5335 Family Service Documentation
[077-100]
(PL
17.4)
P/J115
and the MCU PWB
P/J411
for open
(PL
BUS Updated 12/2011
077-907 Duplex Sensor Static Jam RAP
BSD-ON:
BSD 10. 5 - Duplex
When the power was turned ON, the M/C was stopped (Cycle Down/ Shut Down), or when the
interlocks were closed (all interlocks including options), the Duplex Sensor detected paper.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
•
The Duplex Sensor for remaining paper, contamination, Actuator return failure, or
improper installation
•
The Duplex Sensor for failure:
•
The connection between the Duplex Sensor
circuit, short circuit, and poor contact
Reload the machine software
(GP
18.2).
07/2011
2-813
Component Control
[077-105]
(PL
14.4)
P/J109
and the MCU PWB
16). If no problems are found, replace the MCU PWB
Status Indicator RAPs
077-902, 077-907
P/J409
for open
(PL