116-397 AAAmgr illegal setting area coverage threshold

The Plain Total Color Judge Threshold setting is wrong.
When the condition below is met in setting system data values in boot sequence:
720-061(threshold B) <= 720-060(threshold A)
*If Chain-Link 720-060 Value is not below 720-061 Value, FAULT will be detected.
Initial Actions
Power Off/On
Procedure
1.
Turn the power OFF then ON.
2.
Set up system data values that meet the relation between them as below:
Chain-Link
NVM Read/Write
720-061(threshold B) > Chain-Link 720-060(threshold
A)
*Chain-Link
NVM Read/Write
720-060 Value must be below 720-061 Value.
Initial Issue
WorkCentre 5335 Family Service Documentation

116-399 Initialization RAP

BSD-ON:
BSD 16.1 - ESS
BSD-ON:
BSD 34.1 - FAX
Initialization exceeded 10 minutes.
When 10 minutes had passed after the Pflite has started up, "the machine remains in ini-
tializing state" was detected. => 10 minutes had passed in a situation where neither Ack
nor Nack was returned from any task.
This failure is detected only in startup modes such as "Normal Cold Boot" and "Reboot
Mode (during Diag exit, etc.)". In other modes such as "Recovery from Power Save" and
"Special Boot Mode", the failure is not detected because the timeout time of 10 minutes is
difficult to guarantee.
Reboot the machine once if it remains in initializing state even when the 10-minute
timeout time has passed after power ON.
Obtain the "PfShowInfo8" log and save it in the HDD before rebooting.
"Ready to Copy" is displayed and the error code is not displayed at normal start up
after rebooting.
If 116-399 occurs again after rebooting, the System Fail screen is displayed.
For cases where 116-399 is displayed, the pfshowinfo8 log is obtained twice succes-
sively.
Although the log is saved in the HDD even if 116-399 is not displayed because the
machine cannot shift to the SysFail state, the latest histories might not get logged.
Initial Actions
Power Off/On
Procedure
Reload Software
If the problem persists, replace the ESS PWB
07/2011
2-887
BUS Updated 12/2011
(GP
16).
(PL
35.2).
Status Indicator RAPs
116-397 , 116-399