116-384 DCS Fatal Error RAP
DCS-related fatal error.
Due to an error in software processing, subsequent processes cannot be performed.
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Reinstall or replace the DIMM
(PL
35.2).
•
Remove and re-install or replace the System Memory and Page Memory DIMMs
35.2).
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB
(PL
•
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB)
Initial Issue
WorkCentre 5335 Family Service Documentation
35.2)
BUS Updated 12/2011
116-385 IDC Software RAP
An internal shutdown occurred after an IDC (scripting language) processing error.
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Reinstall or replace the DIMM
•
Remove and re-install or replace the System Memory and Page Memory DIMMs
35.2).
(PL
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB
•
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB)
07/2011
2-881
(PL
35.2).
(PL
35.2)
Status Indicator RAPs
116-384 , 116-385
(PL